Customization: | Available |
---|---|
After-sales Service: | Video Guide |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
picture presentation |
product description |
Product Parameter |
Number of rope layers | layer | First layer | second flayer | third layer | fourth layer | hydraulic principle diagram |
Single rope pull | kgf | 1000 | 905 | 826 | 760 | |
Line speed (56L/min) | m/min | 35 | 37 | 38 | 40 | |
rope capacity | m | 13 | 27 | 43 | 62 | |
Motor displacement | ml/r | BMR200 | ||||
Motor operating pressure | MPa | 10 | ||||
motor output power | kW | 10 | ||||
cable diameter | mm | 10 | ||||
reduction ratio | i | 4.77 | ||||
Static braking moment | N.m | 480 |
Number of rope layers | layer | First layer | second flayer | third layer | fourth layer | hydraulic principle diagram |
Single rope pull | kgf | 2000 | 1830 | 1620 | 1570 | |
Line speed (62L/min) | m/min | 30 | 34 | 37 | 41 | |
rope capacity | m | 120 | ||||
Motor displacement | ml/r | 250 | ||||
Lifting pressure | MPa | 16 | ||||
Maximum motor flow | L/min | 115 | ||||
Maximum motor torque | N.m | 557 | ||||
cable diameter | mm | 10 | ||||
reduction ratio | i | 4.76 | ||||
Static braking moment | N.m | 420 |
First layer tensile force | KN | 30 | hydraulic principle diagram |
Line speed | m/min | 5-50 | |
cable diameter | mm | 12 | |
rope capacity | m | 95 | |
hydraulic system pressure | MPa | 14 | |
Hydraulic system flow | L/min | 75 | |
reduction ratio | 1:5 | ||
Brake opening pressure | MPa | 2.5-3 |